Version: 6.49rc2
Testing14 changelog entries across 10 component(s)
2021-Sep-28 (4 years ago)
| Component | Change |
|---|---|
| bridge | improved controller bridge stability when adding RouterOS v7 port extender; |
| bridge | improved port extender stability when creating bond interfaces on excluded ports; |
| crs3xx | fixed bridge controller and extender packet forwarding for CRS312, CRS326-24S+2Q+ and CRS354 devices; |
| dhcp-server | fixed DHCP Option decimal value parsing; |
| discovery | do not send discovery packets on interfaces that are blocked by STP (introduced in v6.48); |
| sfp | added "sfp-rate-select" setting; |
| supout | added controller bridge section; |
| switch | fixed (R/M)STP port blocking right before switching them in HW bridge (fixes possible packet loop when changing bridge settings); |
| user | added "expired" user status with suggestion to change password (WinBox v3.29 required); |
| user | fixed active user session purging on disconnect; |
| user | show "expired password" prompt for users with blank password; |
| winbox | added "fec-mode" parameter under "Interface/Ethernet" menu; |
| winbox | minimal required version is v3.30; |
| wireless | improved system stability when sending packets through interface after L2MTU is increased; |