7.23beta5 Development 2026-Apr-01 (1 month ago)
  • hide health menu for RB951ui-2nD;
7.22 Stable 2026-Mar-09 (1 month ago)
  • added CPU temperature monitoring to L009 with ARM64;
7.22rc3 Testing 2026-Feb-26 (2 months ago)
  • added CPU temperature monitoring to L009 with ARM64;
7.20.8 Long-term 2026-Jan-30 (3 months ago)
  • fixed fan and PSU state logging for MIPSBE devices;
7.21.1 Stable 2026-Jan-19 (3 months ago)
  • fixed fan and PSU state logging for MIPSBE devices;
7.22beta3 Development 2026-Jan-14 (3 months ago)
  • fixed fan and PSU state logging for MIPSBE devices;
7.21 Stable 2026-Jan-12 (3 months ago)
  • upgraded fan controller firmware to latest version;
7.21beta2 Testing 2025-Oct-06 (6 months ago)
  • upgraded fan controller firmware to latest version;
7.19 Stable 2025-May-22 (11 months ago)
  • hide settings in CLI if there is nothing to show;
  • improved performance on devices with simple voltage sensors;
7.19beta2 Testing 2025-Feb-28 (1 year ago)
  • hide settings in CLI if there is nothing to show;
  • improved performance on devices with simple voltage sensors;
7.17 Stable 2025-Jan-16 (1 year ago)
  • hide settings in CLI if there is nothing to show;
  • removed board-temperature on RB5009UPr+S+IN device;
  • added cpu-overtemp-check on ARM, ARM64 devices (CLI only);
  • changed PSU state from "no-ac" to "no-input";
7.17beta4 Testing 2024-Oct-18 (1 year ago)
  • changed PSU state from "no-ac" to "no-input";
7.17beta2 Testing 2024-Sep-27 (1 year ago)
  • added cpu-overtemp-check on ARM, ARM64 devices (CLI only);
  • hide settings in CLI if there is nothing to show;
  • removed board-temperature on RB5009UPr+S+IN device;
7.16 Stable 2024-Sep-20 (1 year ago)
  • fixed board-temperature for KNOT device (introduced in v7.15);
  • fixed bogus CPU temperature spikes for CCR2216 device;
  • fixed missing health for CRS112-8G-4S device (introduced in v7.15);
  • improved voltage measurements for RB912UAG-6HPnD and RB912UAG-5HPnD devices;
  • removed unnecessary health settings for RB921 and RB922 devices;
  • upgraded fan controller firmware to latest version;
7.16beta4 Testing 2024-Jul-02 (1 year ago)
  • improved voltage measurements for RB912UAG-6HPnD and RB912UAG-5HPnD devices;
7.16beta3 Testing 2024-Jun-27 (1 year ago)
  • removed unnecessary health settings for RB921 and RB922 devices;
7.16beta2 Testing 2024-Jun-12 (1 year ago)
  • improved voltage measurements for RB912UAG-6HPnD device;
7.15.1 Stable 2024-Jun-07 (1 year ago)
  • fixed board-temperature for KNOT device (introduced in v7.15);
  • fixed missing health for CRS112-8G-4S device (introduced in v7.15);
7.16beta1 Testing 2024-Jun-05 (1 year ago)
  • fixed board-temperature for KNOT device (introduced in v7.15);
  • fixed bogus CPU temperature spikes for CCR2216 device;
  • fixed missing health for CRS112-8G-4S device (introduced in v7.15);
  • upgraded fan controller firmware to latest version;
7.15 Stable 2024-May-29 (1 year ago)
  • added "cpu-temperature" for IPQ50xx devices;
  • added log for fan state changes on CRS3xx, CRS5xx, CCR2xxx, CCR1016r2, CCR1036r2 devices;
  • fixed fan behavior for CRS310-1G-5S-4S+ (introduced in v7.14);
  • fixed rogue voltage on CRS510-8XS-2XQ-IN;
7.15beta9 Testing 2024-Mar-27 (2 years ago)
  • fixed missing "cpu-temperature" on IPQ-60xx devices (introduced in v7.15beta8);
7.15beta8 Testing 2024-Mar-21 (2 years ago)
  • added "cpu-temperature" for IPQ50xx devices;
  • fixed fan behavior for CRS310-1G-5S-4S+ (introduced in v7.14);
  • fixed rogue voltage on CRS510-8XS-2XQ-IN;
7.15beta4 Testing 2024-Mar-04 (2 years ago)
  • added log for fan state changes on CRS3xx, CRS5xx, CCR2xxx, CCR1016r2, CCR1036r2 devices;
7.14 Stable 2024-Feb-29 (2 years ago)
  • added limited manual control over fans for CCR1016r2, CCR1036r2 devices;
  • changed default "fan-min-speed-percent" from 0% to 12%;
  • improved fan control on CRS3xx and CCR1016-12S-1S+r2;
  • show voltage when powering KNOT R through Micro-USB;
  • updated health properties for CCR1016r2, CCR1036r2 devices;
7.14beta9 Testing 2024-Feb-01 (2 years ago)
  • added limited manual control over fans for CCR1016r2, CCR1036r2 devices;
  • changed default "fan-min-speed-percent" from 0% to 12%;
  • updated health properties for CCR1016r2, CCR1036r2 devices;